Code,Standards,Practices 2 level 5-A

Horizontales
350, 356, liquidtight flexible metal conduit and liquidtight flexible nonmetallic conduit specifications
300.4(B)(2), ENT Shall Be Protected from Physical Damage with 1/16 inch Minimum Steel Plate
518.4(A), Raceways Encased in 2 inch of Concrete
362.10(8), Uses Permitted with Metric designator 16 to 27 (1/2 to 1 inch)
362.10, First Floor Shall Be the Floor With 50 percent or More of the Exterior Wall Surface Level With or Above Finished Grade
Verticales
362.10, Can Be Used in Residential, Commercial, Schools, Condominiums, Apartments, and Industrial Applications
Chapter 9 Table 1, The Cross Sectional Area Calculation for Wire Fill Shall Be Based on the Major Diameter of the Ellipse of the Conductor or Cable System
Common Name for ENT, its BLUE
362.30, Horizontal Not Exceeding 3 feet and At Terminations
362.20(B), ENT Larger Than 2 1/2 inch Shall Not Be Used